meta data for this page
Lemoine Network Translator Server
1. Find Servers MAC Address and Name and send to Lemoine so license can be
requested.
2. Copy the Network Translator Server folder into the C:\Program Files (x86)\Lemoine
Technologies\Rtm Version 7\Network Translator Server. This can be requested from
Lemoine if you do not have this folder.
3. Obtain the Crosscadware.dll and Config.dtk from Lemoine and copy them into the
following folders.
Crosscadware.dll - C:\Program Files (x86)\Lemoine Technologies\Rtm Version 7
Config.dtk - C:\Users\Public\AppData\Lemoine\Rtm\Config
4. Locate the lmtool.exe in the C:\Program Files (x86)\Lemoine Technologies\Rtm
Version 7\Network Translator Server. Right click on the lmtools.exe and select “Run
as Administrator”.
5. This window will appear-
Goto the Config services and fill in the necessary fields.
6. Config Services- Type in the Service Name. It should be” Lemoine Translator
Service”.
Path to the Imgrd.exe file -C:\Program Files (x86)\Lemoine Technologies\Rtm
Version 7\Network Translator Server
Path to the License File-C:\Program Files (x86)\Lemoine Technologies\Rtm Version
7. Network Translator Server. LIC file should be placed in this folder once received
from Lemoine.
Path to the Debug log file- C:\ProgramData\FNP_DIR\debug.log- This never
changes!
Once completed select the” Save Services” button. This will add the services to the
list.
7. Make sure that the Server name is correct, and the IP Address are correct.
8. The utilities tab should be empty.
9. The Start/Stop/Reread tab make sure it says Lemoine Translator Services and select
Start Server.
10. Server Status tab. This tab should be blank.
11. Server Diags- This tab should be blank.
12. Borrowing- This field should be left with the defaults.
13. The System variable needs to be created in the Environment Variable. Go to the
Environment Variables and select “New…” under the System Variable (NOT a USER
Variable!)
Variable Name: Datakit_License_File
Variable Value: 27000@(servername here)
C:\Users\Public\AppData\Lemoine\Rtm\Config
14. In the Services make sure that the Lemoine Translator Service is running and set to
Automatic.
Make sure that the following services are running and set to automatic:
15. Once these steps are complete you now need to restart the server.
Setting up the Clients to use the new Network Translator License
1. Copy the new Crosscadware.dll in to the- C:\Program Files (x86)\Lemoine
Technologies\Rtm Version 7
2. Copy the Config.dtk in to -C:\Users\Public\AppData\Lemoine\Rtm\Config
3. Set the Environment Variable on the Client computer.
4. The System variable needs to be created in the Environment Variable. Go to the
Environment Variables and select “New…” under the System Variable (NOT a
USER Variable!)
Variable Name: Datakit_License_File
Variable Value: 27000@(servername here)
Reboot computer and Import a file to test.